LR/HR

The LR/HR method was developed from the original Shock Pulse Method for condition diagnosis of rolling element bearings. It allows a precision analysis of oil film condition in the rolling interface and contains calculation models for finding the optimal lubricant. Poor lubrication is the root cause of most bearing failures.

Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

Throughout their lifetime, bearings generate shocks in the interface between the loaded rolling element and the raceway. These shocks 'ring' the SPM transducer which outputs electric pulses proportional to the shock magnitude. Unlike vibration transducers, the shock pulse transducer responds at its carefully tuned resonance frequency of about 32 kHz, which allows a calibrated measurement of the shock pulse amplitudes.

Measuring LR/HR

Transducer and measuring procedure are the same as for the dBm/dBc method. The shock pulse meter counts the rate of occurrence (incoming shock pulses per second) and varies the gain until two amplitude levels are determined:

  • - HR = high rate of occurrence, quantifying the shock carpet (approx. 1000 incoming shocks per second).
  • - LR = low rate of occurrence, quantifying the strong shock pulses (approx. 40 incoming shocks per second).

LR and HR are 'raw values', measured in dBsv (decibel shock value).

Input data

The LR/HR method requires more precise data on the bearing, because bearing geometry, as well as size and speed, affect the shock carpet and thus the analysis of oil film condition in undamaged bearings. The rpm is needed, plus a definition of the bearing type and size. This is best input by stating the ISO bearing number, which links to the bearing catalogue in Condmaster.

Evaluation

After measurement the measuring device returns

  • - a general description of bearing condition (CODE)
  • - a value for oil film condition (LUB)
  • - a value for surface damage (COND)

A LUB no. of 0 means dry running, the value increases with oil film thickness. A COND no. of around 30 indicates surface stress or early damage, the value increases with damage severity. The general assessment is:

CODE A Good bearing
CODE B Poor lubrication
CODE C Dry bearing, risk of damage
CODE D Damage

A program part, LUBMASTER, uses the shock values plus data on lubricant type, viscosity, load and operating temperature to calculate the bearing's life expectancy under present condition. It also calculates the effect of changes in oil type and viscosity.

Calibration

The accuracy of the LR/HR method is increased by a calibration factor (COMP no.) used in case of bearings with minimal load or poor quality measuring points (in both cases the signal strength is below normal). On the basis of the bearing's catalogue data and the lubricant properties, Leonova calculates the normal shock level for a good bearing and compensates for an abnormally low signal before returning the evaluation results.

Analyzing LR/HR (SPM Spectrum™)

The purpose of 'SPM Spectrum' is to verify the source of high shock pulse readings. Shocks generated by damaged bearings will typically have an occurrence pattern matching the ball pass frequency over the rotating race. Shocks from e. g. damaged gears have different patterns, while random shocks from disturbance sources have none.

Signal and measurement

The result from the LR/HR measurment is the bearing condition data, evaluated green - yellow - red. A second measurement produces a time record that is subjected to a Fast Fourier Transform (FFT). The resulting spectrum is used mostly for pattern recognition. Spectrum line amplitudes are influenced by too many factors to be reliable condition indicators, so all condition evaluation is based on the dBm or the HR values.

One unit for amplitude in an SPM spectrum is SD (Shock Distribution unit), where each spectrum is scaled so that the total RMS value of all spectrum lines = 100 SD = the RMS value of the time record. The alternative is SL (Shock Level unit), the RMS value of the frequency component in decibel. Alarm levels are manually set for each symptom to show evaluated results in green - yellow - red. Various types of spectra can be produced. The recommended setting is a spectrum with a resolution of at least 0.25 Hz, e. g. 3200 lines over 500 Hz, saving peaks only.

Input data

Pattern recognition demands precise data on the bearing and exact measurement of the rpm. The rpm should be measured, not preset. The factors defining the bearing frequencies are obtained from the bearing catalogue in Condmaster by stating the ISO bearing number.

Evaluation

The frequency patterns of bearings are preset in Condmaster. Linking the symptom group 'Bearing' to the measuring point allows the user to highlight a bearing pattern by clicking on its name. Other symptoms can be added when appropriate, e. g. for gear mesh patterns. Finding a clear match of a bearing symptom in the spectrum is proof that the measured signal originates from the bearing.